Minimum Order Quantity | 5 Piece |
No Of Unit To Be Tested | 5 |
Application Type | Industrial |
Mode of Report | Hard Copy |
Test Location | In Laboratory |
Need Test Result | 10 To 12 DAYS |
Query Response Time | 630PM |
Need Standard Certification | Yes |
1 | Purity Analysis in Pharmaceutical Raw Material & Finished Products as per IP/BP/USP |
2 | Vitamins analysis |
3 | Dyes & Intermediate |
4 | Color Control |
Minimum Order Quantity | 5 Piece |
Features | Work In Proper Way |
Service Duration | 10 to 12 days |
Type Of Service Provider | any types |
Training Course Required | No |
Ion Source | Metal |
Mass Range | Not Fixed |
Dynamic Range | Dependent On Accuracy |
Need Test Result | >24 Hours |
Service Availability | Yes |
Color | Light White |
Spectrometer Testing Service
We Have Expertise In Offering World Class Spectrometer Testing Service
All Types Of Material Testing Services.
Minimum Order Quantity | 5 Piece |
Mode Of Report | Soft Copy,Hard Copy |
Test Location | In Laboratory |
Service Duration | 10 to 12 days |
Query Response Time | ONLY AND ONLY IN MAIL |
Need Standard Certification | Yes |
Service Location | IN LABORATORY |
We Have Analysis/Testing The Melting Point As Per Requirements Of Client With Humbly Satisfaction.
All Types Of Material Testing Services Available In Our Laboratory.
*Your information is safe with us.
Minimum Order Quantity | 5 Packet |
Certification Service | ISO |
Application Area | Viscosity Meter Testing |
Query Response Time | 630pm |
Industry Type | Instrumentation |
Physical Parameter Test | Yes,Depend On Requirement |
Sample Percentage | 100% |
1 | Measurement range: 25 mPa s1×107 mPas (If choosing the No.30 spindle, the measurement range can extend to 2 × 107 mPas) |
2 | Spindle: No. 21, 27, 28, 29 total four types of spindles (the No.30 is optional) |
3 | Spindle speed: 0.1, 200 RPM, continuously speed regulation (With 12 grades of speed) |
4 | Measurement error: ±2% (FS), choosing the No.30 spindle, it will be ±3% (FS) |
5 | Temperature controlling range: 25, 200 |
6 | Temperature controlling accuracy: ±0.1 |
7 | Sample cylinder cubage: 20 ml |
8 | Power supply: AC 220 V±10%, 50 Hz |
9 | Ambient temperature: 5,35 (when the control temperature of the heater is close to the ambient temperature, turn on the air conditioner to allow the ambient temperature is approximately 5 lower than the control temperature of the heater) |
10 | Relative humidity: ≤80% |
We Have Analysis/Testing The Vicosity As Per Requirements Of Client With Humbly Satisfaction.
All Types Of Material Testing Services Available In Our Laboratory.
Minimum Order Quantity | 1 Piece |
Mode of Report | Hard Copy |
Test Location | In Laboratory |
Value Data Report on | Material Properties |
Sampling Area | By Samples in Lab |
Service Duration | 10 TO 12 Days |
Standard Certificates | ISO |
Service Location | Ahmedabad |
Number of Devices | >4 |
Type Of Service Provider | All Types |
Training Course Required | No |
Need Test Result | Other |
Part Of Used | Any |
Query Response Time | 6.30pm |
Need Standard Certification | Yes |
We Have Expertise In Offering World Class ICP MS Instrument Products Testing Service
All Types Of Material Testing Services.
Minimum Order Quantity | 5 Piece |
Mode Of Report | Soft Copy, Hard Copy |
Test Location | In Laboratory |
Service Duration | 10 to 12 days |
Destination | 10 to 13 Days |
Type Of Service Provider | any types |
Need Test Result | 10 To 12 DAYS |
Query Response Time | 630PM |
Need Standard Certification | Yes |
XRD Testing Services
We Have Expertise In Offering World Class XRD Testing Service
All Types Of Material Testing Services.
*Your information is safe with us.
Minimum Order Quantity | 5 Piece |
Mode of Report | Hard Copy |
Test Location | In Laboratory |
Any Specific Test Criteria | Yes |
Need Test Result | 10 To 15 Days |
Query Response Time | 630pm |
Need Standard Certification | Yes |
Need Test Report | Yes |
Physical Parameter Test | Yes |
1 | GenTech Master Gas Chromatograph (GC) |
2 | User-Friendly Touch Screen Interface |
3 | DPC - Patented Digital Flow Control |
4 | Constant Linear Velocity Mode |
5 | Pulsed Injection |
6 | Gas Saving and Leak Checking System |
7 | Reduced Sample Run Times |
8 | Complete Range of Highly Sensitive Detectors |
9 | Three Injection Ports and Three Detectors |
10 | Clarity(TM) Work Station - compatibility |
11 | Versatile System Design |
12 | Column Oven 1 - 500 DegreeC |
13 | Analytical Methods Capacity of 25 |
14 | Digital Pneumatic Control Pressure Range of up to 120 psi |
15 | Typical Cooling Time of 4 Minutes |
16 | Narrow Bore of Fast GC Columns of 50 - 2000 mm I.D. |
17 | Typical Peak Widths of 0.5 Seconds or Less |
18 | Conventional GC Application is 161.228 (split 2,20) |
19 | Fast GC Application |
20 | Signal-to-Noise Ration of 2, 2'', 5'' |
21 | Increased Sensitivity |
Minimum Order Quantity | 5 Packet |
Mode of Report | Hard Copy |
Test Location | In Laboratory |
Sampling Area | Off-Site Testing |
Service Duration | 12 Days |
Any Specific Test Criteria | Yes |
Need Test Result | 10 To 13 Days |
Query Response Time | 630pm |
Need Standard Certification | Yes |
Need Test Report | Yes |
Physical Parameter Test | Yes |
1 | Heavy Metal/Trace Metals Analysis |
2 | Copper |
3 | Lead |
4 | Zinc |
5 | Chromium |
6 | Cadmium |
7 | Aluminum |
8 | Nickel |
9 | Iron |
10 | Silver |
11 | Cobalt |
12 | Tin |
1 | FLAME: For ppm level analysis |
2 | GFA: For ppb/ppt level analysis |
3 | HVG: For ppb level analysis of Arsenic, Selenium, Mercury, Antimony etc |
We Have Analysis/Testing The Aas As Per Requirements Of Client With Humbly Satisfaction.
All Types Of Material Testing Services Available In Our Laboratory.
Minimum Order Quantity | 1 Unit |
Mode of Report | Hard Copy |
Test Location | In Laboratory |
Service Duration | 10 Days |
Need Test Result | 10 To 13 Days |
Query Response Time | 630pm |
Need Standard Certification | Yes |
LCMS is a hyphenated technique, combining the separation power of HPLC, with the detection power of mass spectrometry. Even with a very sophisticated MS instrument, HPLC is still useful to remove the interferences from the sample that would impact the ionization.
Closely related to LC/MS are some other techniques, like flow injection/MS, CE or CEC/MS, capillary LC or nano LC/MS In all cases, there is the need for an interface that will eliminate the solvent and generate gas phase ions, then transferred to the optics of the mass spectrometer.*Your information is safe with us.
Minimum Order Quantity | 5 Piece |
Metal To be analysed | It's Depend On Client Requirement |
Product Type | Any |
Mode of Report | Hard Copy |
Need Standard Certification | Yes |
Humidity Measurement Required | Yes |
Mechanical Properties Testing Required | Yes |
Micro Biological Testing | Yes |
Test Report Required | Yes |
Failure analysis is the mechanical, physical, and chemical investigation into the cause and sequence of events that lead to a product condition in which the product no longer meets expectations.
If your product or component fails or does not perform as expected, Akshar laboratory applies materials science to provide the actionable information you need for continuous improvement efforts and warranty analysis.
Failure analysis testing can be valuable in any situation where knowing the true causes of a failure will fundamentally improve engineering and management decisions. Our materials, chemical, metallurgical, and mechanical testing experts will guide you through the entire process.
We work according to your schedule, ensuring that your project is completed quickly and on budget.
FAILURE ANALYSIS PROCESS :
At begins each investigation with a background review of the material or part that failed. Whenever possible, customers provide us with all pertinent information, including:
· Composition and fabrication of the failed item
· Circumstances leading to the failure
· Details of the failure event by completing our Failure Analysis Questionnaire
Based on the type of product and its history, engineers will perform a root cause failure analysis using the necessary testing and inspections to identify the cause of failure.
A metallurgical failure analysis may include any of the wide-range of mechanical testing, metallurgical evaluation, chemical analysis, nondestructive testing or dimensional inspection services performed.
Testing and inspection are performed using top-of-the-line equipment throughout the Lab, including our Scanning Electron Microscope with EDS capabilities. We can get the structural and behavioral results necessary for a thorough investigation and to uncover the probable root cause of the failure, including:
· Material composition
· Mechanical properties
· The existence of flaws or inconsistencies
When the failure analysis is completed, customers receive a comprehensive Failure Analysis Report with all findings from the investigation. This Report may include recommended actions to be taken with similar parts or materials to prevent a reoccurrence in the future.
FAILURE ANALYSIS CAPABILITIES
· Failure Investigation
· Testing & Inspection
· Failure Analysis Report
· Assistance with Expert Witness
We Have Analysis/Testing The Failure As Per Requirements Of Client With Humbly Satisfaction.
All Types Of Material Testing Services Available In Our Laboratory.
Minimum Order Quantity | 5 Piece |
Testing Rate | Dependent On Parameter |
Physical Test | Yes |
Chemical Test | Yes |
Total Analysis Possibly | Yes |
Time Period | 10 To 13Days |
Rate | Depend On Parameter |
Thermal Elemental Testing Services
A Flash EA 1112 Series Elemental Analyser (EA) connected via a Conflo III to a DeltaPlus XP isotope ratio mass spectrometer (all Thermo Finnigan, Bremen, Germany); for the determination of Nitrogen and carbon isotopes in solid samples such as soil and plant material. The Flash EA can be substituted with a High Temperature Conversion EA (TC/EA) allowing determination of hydrogen and oxygen isotopes.
We Have Analysis/Testing The Thermal As Per Requirements Of Client With Humbly Satisfaction.
All Types Of Material Testing Services Available In Our Laboratory.
Minimum Order Quantity | 5 Piece |
Mode of Report | Hard Copy |
Test Location | In Laboratory |
Application Type | Industrial |
Need Test Result | 10 To 12 Days |
No Of Unit To Be Tested | 5 |
Query Response Time | 630pm |
Need Standard Certification | Yes |
1 | Tank Size: 238 x 135 x 100 mm deep x 3 Litre capacity. |
2 | This compact unit offers unrivalled cleaning performance ensuring test pieces and components are thoroughly and consistently cleaned, pre dye penetrant inspection |
3 | Ideal size for PSM-5 Penetrant Panels, test pieces and smaller components |
4 | Safe fast and effective cleaning |
5 | Robust and reliable |
6 | Inexpensive and efficient |
7 | 2 year warranty |
8 | Power: 85 W |
9 | Weight: 3.6 Kg |
10 | External dimensions L 265 W 162 H 250 |
11 | 220-240v 50Hz Operation |
12 | Easy to use with simple on/off switch for the ultrasonics |
13 | Stainless lid and mesh basket available if required |
14 | Larger baths also available upon request |
3.4/5
Rated by 21 Users